IDD12 - EXPERIMENTAL ASSESSMENT TECHNIQUES FOR SEISMIC ISOLATION AND ENERGY DISSIPATION DEVICES |
TUESDAY | ||||||||
AMBER 2 | Convenors: M. Furinghetti, A. Pavese, F. Ponzo, P. Dubini, D. De Domenico | ||||||||
14:30 - 14:40 | TESTING OF SEISMIC ISOLATORS M. Constantinou | |||||||
14:40 - 14:45 | STATISTICAL ANALYSIS OF THE EXPERIMENTAL RESPONSE OF FULL-SCALE SEISMIC PROTECTION DEVICES M. Furinghetti, P. Dubini, C. Curti, M. Bazzini, S. Reale, A. Pavese | |||||||
14:45 - 14:55 | HYBRID TESTING WITH MODEL UPDATING OF A BRIDGE WITH SEISMIC ISOLATION INCORPORATING ROTATION M.C. Lopez Ruiz, M. Cheng, T. Becker | |||||||
14:55 - 15:05 | DESIGN AND SHAKE TABLE TESTING OF 3-D SEISMIC ISOLATION FOR CRITICAL EQUIPMENT I. Aiken, C. Black, B. Lawrence, A. Zhang, N. Cheang, M. Mohammed, A. Ibrahim, P. McLean | |||||||
15:05 - 15:15 | A PASSIVE CONTROL SYSTEM BASED ON DOUBLE U-SHAPED METAL ELEMENTS: REAL CASES, DESIGN AND DEVELOPMENT M.C. Castino, A.M. Cicalese | |||||||
15:15 - 15:25 | BASE ISOLATION AND SUPPLEMENTAL ENERGY DISSIPATION: A BIG STEP TOWARD RESILIENT STRUCTURES M. Sartori | |||||||
15:25 - 15:32 | MODEL-BASED DESIGN AND EXPERIMENTAL VERIFICATION OF ADAPTIVE CURVED SURFACE SLIDER SIP®-ADAPTIVE F. Weber, F. Bomholt, P. Huber, C. Braun | |||||||
15:32 - 15:39 | TEMPORARY CONNECTION DEVICES ACCORDING TO EN15129: STUDY OF THE CURRENT EUROPEAN TESTING STANDARD. S. Infanti, A.E. Pigouni | |||||||
15:39 - 15:45 | OVER-STROKE EFFECTS ON SEISMIC FRAGILITY OF RC FRAME BUILDINGS RETROFITTED WITH DCCSS ISOLATORS N. Lamarucciola, A. Di Cesare, F. Daraio, F.C. Ponzo | |||||||
WEDNESDAY | ||||||||
MONITOR 16 | Convenors: M. Furinghetti, A. Pavese, F. Ponzo, P. Dubini, D. De Domenico | ||||||||
09:00 - 09:09 | PUSH-AND-RELEASE TESTS OF HYBRID ISOLATION SYSTEMS: EXPERIMENTAL RESULTS AND MODEL CALIBRATION F. Micozzi, A. Poeta, L. Gioiella, L. Ragni, A. Dall Asta | |||||||
09:09 - 09:18 | A UNIFIED APPROACH TO SIMULATE THE UNIAXIAL HYSTERETIC BEHAVIOR EXHIBITED BY ELASTOMERIC BEARINGS N. Vaiana, L. Rosati | |||||||
09:18 - 09:27 | INNOVATIVE SETUP AND TESTING METHODOLOGY OF A NOVEL BIDIRECTIONAL ROTATION FRICTION DAMPER (BRFD) E. Grossi, R. De Risi, M. Zerbin, F. De Luca, A. Aprile | |||||||
09:27 - 09:36 | RETROFIT OF EXISTING MASONRY BUILDINGS THROUGH SEISMIC ISOLATION: RECENT APPLICATIONS IN ITALY S. Barone, R. Vetturini, W. Cecchini, L. Trombettoni | |||||||
09:36 - 09:45 | REAL-TIME HYBRID SIMULATION FOR INVESTIGATING THE SEISMIC PERFORMANCE OF LEAD RUBBER BEARINGS J. Park, M. Park, Y. Chae, C. Kim | |||||||
09:45 - 09:54 | APPLICATION OF SQUARE HOLLOW SECTION OUTER TUBE TO BRB USING MULTIPLE STEEL BAR CORES S. Zhang, H. Tagawa, X. Chen | |||||||
09:54 - 10:03 | ESTIMATION OF THE ISOLATION LAYER STIFFNESS BASED ON OBSERVED GROUND MOTION AND MAXIMUM DISPLACEMENT T. Miyauchi, T. Hirai, Y. Nagano | |||||||
10:03 - 10:12 | COMPRESSION-SHEAR LOADING TEST OF COMPLETELY RUPTURED LEAD RUBBER BEARING WITH A LARGE DIAMETER. R. Umemura, K. Kanazawa, T. Hiraki | |||||||
10:12 - 10:21 | DEVELOPMENT AND HYBRID TESTING OF RING SPRING SELF-CENTERING ENERGY DISSIPATIVE BRACES A. Hassan, J. Erochko, C. Flude, D. Lau | |||||||
MONITOR 17 | Convenors: M. Furinghetti, A. Pavese, F. Ponzo, P. Dubini, D. De Domenico | ||||||||
09:00 - 09:09 | EXPERIMENTAL EVALUATION OF VARIOUS DEPENDENCES IN FULL-SCALE RUBBER BEARING UNDER DYNAMIC LOADING M. Kobayashi, K. Sakai, M. Kurosawa, S. Kishiki | |||||||
09:09 - 09:18 | OPTIMAL SET-UP CONFIRGUATION FOR TESTING STIFF ENERGY-DISSIPATING DEVICES UNDER LARGE DISPLACEMENTS G. Bozzo, L. Perez, E. Miranda, J. Báiran, L. Bozzo | |||||||
09:18 - 09:27 | EXPERIMENTAL RESEARCH OF ISOLATING RUBBER BEARINGS CONSIDERING THE EFFECT OF AMBIENT TEMPERATURE J. Dai, H. Pang, T. Jiang, Y. Yang, W. Bai | |||||||
09:27 - 09:36 | EXPERIMENTAL STUDY ON TEMPERATURE FIELD OF RUBBER BEARINGS CONSIDERING HEATING EFFECT OF LEAD CORE B. Xue, W. Lu, X. Ren, H. Zhang | |||||||
09:36 - 09:45 | LOW-COST TUNED MASS DAMPING LATERALLY SLIDING WITH STAINLESS STEEL BALLS AND SPRING-LOADED RESTRAINT V.R. Ramirez Marquez | |||||||
09:45 - 09:54 | RESILIENCE OF BUCKLING-RESTRAINED BRACES FABRICATED IN COLOMBIA BASED ON FATIGUE TESTING J. Oviedo-Amezquita, N. Jaramillo-Santana, C. Blandon-Uribe, A. Bernal-Zuluaga | |||||||
09:54 - 10:03 | SHAKE TABLE TEST OF A CAPABLE AND RESILIENT LATERAL SEISMIC ISOLATION SYSTEM FOR LONG-SPAN BRIDGES Z. Guan, J. Li | |||||||
10:03 - 10:12 | SHAKING TABLE TEST STUDY OF THE PERFORMANCE OF SEISMIC ISOLATION SYSTEM FOR A ULTRA HIGH VOLTAGE TRANSFORMER EQUIPMENT Z. Liu |